●Fit for pipe size from 3/4″/ 20mm to 8″/ 200mm
●LK01A: Die-casting aluminum alloyed housing
LK01B: Painted steel housing
●R3/4″or R1″BSPP or NPT connection thread for optional
●Protection class: LK01A IP64 LK01B IP54
●Rated voltage and current: 250VAC, 15 (6) A
●Working pressure: 1.0Mpa/145psi
●Max. testing pressure: 1.5Mpa/218psi
●Max. fluid temperature: 110℃ /230℉
Model |
Fitted pipe size |
Blade length (mm/inch) |
Flow rate with minimum setting (m3/h/gpm) |
Flow rate with maximum setting (m3/h/gpm) |
Switch action |
Switch return |
Switch action |
Switch return |
LK01A-20
LK01A-25
LK01B-20
LK01B-25 |
3/4″/ 20mm |
29/1.14 |
1.0/0.23 |
0.3/0.07 |
2.0/0.45 |
1.5/0.34 |
1″/ 25mm |
34/1.34 |
1.1/0.25 |
0.5/0.11 |
2.0/0.45 |
1.6/0.36 |
11/4″/ 32mm |
34/1.34 |
1.2/0.27 |
0.7/0.16 |
2.6/0.59 |
2.0/0.45 |
11/2″/ 40mm |
57/2.24 |
1.6/0.36 |
1.0/0.23 |
3.3/0.74 |
2.6/0.59 |
2″/ 50mm |
57/2.24 |
3.2/0.72 |
2.2/0.50 |
6.6/1.49 |
6.1/1.37 |
21/2″/ 65mm |
88/3.46 |
4.2/0.95 |
3.2/0.72 |
8.0/1.80 |
7.0/1.59 |
3″/ 80mm |
88/3.46 |
6.3/1.42 |
4.7/1.06 |
12.0/2.72 |
11.0/2.48 |
4″/ 100mm |
88/3.46 |
8.5/1.91 |
6.0/1.35 |
18.0/4.05 |
17.0/3.83 |
5″/ 125mm |
167/6.57 |
13.1/2.95 |
9.0/2.03 |
27.0/6.08 |
25.0/5.63 |
6″/ 150mm |
167/6.57 |
17.2/3.87 |
12.0/2.70 |
33.0/7.43 |
31.0/6.98 |
8″/ 200mm |
167/6.57 |
47.0/10.58 |
39.0/8.78 |
94.0/21.15 |
91.0/20.48 |